Lown - Defibrillator Analyzer
Arkmeds easy to use defibrillator analyzer to ensure a top performance of life-support cardiac-resuscitation equipment. Designed to perform tests with easy, Arkmeds Lown is the ultimate choise of defibrillator analyzer.
Key Features
Automatic shock wave detection
Integrated Pacemaker
Intuitive use
Features
-
Multi-language;
-
LCD 7 inch Screen Touch Screen;
-
Robust, resistance, versatile on the field;
-
Bluetooth connection with app;
-
Graphical Wave Visualization;
-
Oscilloscope output, ECG Amplitude and charge;
-
Remote Access for Lown Maintenance/Update by Archmeds;
-
AED compatibility;
-
12-lead ECG simulation;
-
Long lasting, rechargeable battery.
General |
|
Operating Temperature |
10 °C a 40 °C (50 °F to 104 °F) |
Storage temperature |
-20 °C to +60 °C (-4 °F to +140 °F) |
Humidity |
10 % a 90 % non-condensing |
Dimesions |
(L)261mm x (H)212mm x (W)88mm |
Display |
7 Inches LCD Display |
Communications |
Wifi e Bluetooth |
Battery Charger |
100 - 240 V 50/60 Hz |
Battery |
12V e 6,6 Ah (on for 8 hours, according to usability) |
Weight
|
2 Kg |
ECG |
|
Amplitude |
0,5 a 2,5 mV |
Amplitude Variation |
± 2 % |
Pulse Rate |
Normal sinus - 30 - 300 bpm |
Ritmo Irregular - 30 - 300 bpm |
|
Atrial flutter- 30 - 300 bpm |
|
Asystole - 30 - 300 bpm |
|
Atrial fibrillation fine - 200 - 300 bpm |
|
Artrial fibrillation course - 200 - 300 bpm |
|
Triangular wave - 120 - 300 bpm |
|
Sine wave - 120 - 300 bpm |
|
Frequency Variation |
± 1 % |
Heart Rhythms |
Sinusal, Irregular, Atrial Fibrillation, Asystole, Fine and Gross Ventricular Fibrillation, Triangular and Sinusoidal Wave |
Energy |
|
Range (test) |
0.1 a 400J |
Energy Resolution |
0.1 J |
Reading variation |
± 2% |
Load Resistance |
50 Ohm ± 2% |
Voltage Range |
0 a 5000V |
Voltage Reading Variation |
± 3% |
Current Range |
0 a 100A |
Current Reading Variation |
± 3% |
Current Resolution |
0.1A |
Delay range
|
0 a 100ms |
Delay Reading Variation |
< 0.4ms |
Synchronization |
|
Measurement |
Peak of ECG R wave to peak of defibrillation pulse |
Range |
0 a 100ms |
Synchronization Accuracy |
< 0.4ms |
Timer |
|
Range |
0 a 59 min |
Pacer |
|
Default Resistance
|
25 Ω |
Range Resistance |
25 Ω / 50 Ω/ 75 Ω/ 100 Ω / 125 Ω/ 150 Ω / 175 Ω / 200 Ω / 500 Ω / 600 Ω / 1000 Ω/ 1500 Ω |
Voltage Range
|
0.1V a 33V |
Voltage Reading Variation |
± 0.5V |
Current Range |
0.1A a 1.3A |
Current Reading Variation |
± 0.5A |
Frequency |
5 a 200 BPM |
Frequency Reading Variation |
± 0.5 BPM |
Waller - Patient Simulator
Arkmeds' Waller was designed to make all patitent simultation tests easier and quicker, helping to achieve your medical device quality requirements to ensure patient safety.
Key Features
6-in-1 multifunction simulator tests ECG - including fetal ECG and arrhythmias, respiration, temperature, IBP, NIBP and SpO2 (sold separately)
Features
-
Multi-language;
-
LCD 7 inch Screen Touch Screen;
-
Robust, resistance, versatile on the field;
-
Bluetooth connection with app;
-
12-lead ECG simulation;
-
Stay-connected ECG posts for easy/secure ECG snap and lead connections;
-
Equipment update via remote access to include new SpO2 curves;
-
Flexibility in entering new parameters;
-
Long lasting, rechargeable battery.
General |
|
Operating Temperature |
10 °C a 40 °C (50 °F to 104 °F) |
Storage Temperature |
-20 °C to +60 °C (-4 °F to +140 °F) |
Humidity |
10 % a 90 % non-condensing |
Dimensions |
(L)261mm x (H)212mm x (W)88mm |
Display |
7 Inches |
Communication |
Wifi e Bluetooth |
Battery Charger
|
100 - 240 V 50/60 Hz |
Battery |
12V e 6,6 Ah (duration of 8 hours, according to the mode of use) |
Weight |
Xxx Kg |
ECG |
|
Amplitude |
0,5 a 2,5 mV |
Amplitude variation |
2 % |
Frequency |
Sinus Rhythm - 30 - 300 bpm |
Irregular Pace - 30 - 300 bpm |
|
Atrial Fibrillation - 30 - 300 bpm |
|
Asystole - 30 - 300 bpm |
|
Fine Ventricular Fibrillation - 200 - 300 bpm |
|
Gross Ventricular Fibrillation - 200 - 300 bpm |
|
Triangular Wave - 120 - 300 bpm |
|
Sinusoidal Wave - 120 - 300 bpm |
|
Frequency Variation |
1 % |
Ritmos Cardíacos |
Sinusal, Irregular, Atrial Fibrillation, Asystole, Fine and Gross Ventricular Fibrillation, Triangular and Sinusoidal Wave |
NIBP |
|
Frequency |
80 a 140 bpm |
Pressure Range |
300 mmHg |
Pressure variation |
+/- 1 mmHg |
Test range (mmHg) |
60/30 80/50 100/65 120/80 150/100 170/125 |
Test pressure variation* |
+- 4mmHg |
Unit of measurement |
mmHg |
Leak Test Time |
0 a 99 min e 59 seg |
Temperature |
|
Range (°C ) |
25/33/34/35/36/37/38/39/40/41/42/43/44/45 |
Variation |
+- 0,5 °C |
Compatibility |
YSI Standards - Series 400 e 700 |
Breathing |
|
Derivations |
II e III |
RPM range |
15 a 150 |
PI |
|
Sensitivity |
5 e 40 |
Dynamic Pressure Range (mmHg) |
60/30 80/50 100/65 120/80 150/100 170/125 |
Static Pressure Range (mmHg) |
0 - 300 |
BPM range |
55 - 300 |
SpO2 |
|
Frequency |
30 a 240 bpm |
Saturation |
80/85/90/95/97/98/99/100% |
Beginner
$ 35 .00
/ month- Basic sales & marketing for up to 2 users
- Account & Sales management
- No customization
- No support
Instant setup, satisfied or reimbursed.
Order nowProfessional
$ 65 .00
/ month- Complete CRM for any size team
- Get access to all modules
- Limited customization
- Email support
Instant setup, satisfied or reimbursed.
Start nowExpert
$ 125 .00
/ month- Unlimited CRM power and support
- Get access to all modules and features
- Unlimited customization
- 24x7 toll-free support
Instant setup, satisfied or reimbursed.
Contact usTesla - Eletrical Safety Analyzer
Tesla was build to be the perfect analyzer for eletrical safety with all the necessary tests to ensure the proper functioning of medical devices.
Focused on increasing productivity and minimizing errors, Tesla provides complete automation for IEC 60601 and IEC62353 compliance.
Key Features
Fully integrated with Arkmeds CMMS
Compliance with IEC 60601 and IEC 62353 Standards
Features
-
Multi-language;
-
LCD 7 inch Screen Touch Screen;
-
Robust, resistance, versatile on the field;
-
Bluetooth connection with app;
-
Automated Testing via Software;
-
10 easy-to-use insulated applied parts connection;
-
Test presets - predefined tests for use in class I and class II equipment;
-
Custom Tests Checklist;
-
Flexibility in entering new parameters;
-
Long lasting, rechargeable battery.
Geral |
|
Operating Temperature
|
10 °C a 40 °C (50 °F to 104 °F) |
Storage temperature |
-20 °C to +60 °C (-4 °F to +140 °F) |
Humidity
|
10 % a 90 % non-condensing |
Dimensions
|
(L)261mm x (H)212mm x (W)88mm |
Display |
7 Polegadas |
Communications
|
Wifi e Bluetooth |
Battery Charger
|
100 - 240 V 50/60 Hz |
Battery
|
12V e 6,6 Ah (duration of 8 hours, according to the mode of use) |
Weight
|
2 Kg |
Ground Resistance |
|
Range |
0.1 Ω a 10.0 Ω |
T olerance |
± 1% + 0.5 ohm |
Insulation Test |
|
Range |
0 MΩ a 200 MΩ (applied voltage - 500VDC) |
Leakage Current |
|
Range - Tolerance
|
• 0μA - 500μA (DC a 1kHz - ± 1%) • 500μA - 1mA (1kHz a 100kHz - ± 2,5%) • 1mA - 2mA (100kHz a 1MHz - ± 5%) • 2mA - 12mA (100kHz a 1MHz - ± 5%) |
Functional Current |
|
Range |
0.1 A a 15.0A* |
Tolerance
|
± 5% |
Network Voltage |
|
Range |
100 a 240V RMS |
Tolerance |
± 1% |
Apparent Power |
|
Range |
0.1 VA a 1920 VA |
Tolerance |
± 5% |
General |
|
Charging Time Measurement | 0.1s to 655s |
Voltage Range | 0 - 5000 V |
Current Range | 0 - 120 A |
Others |
ECG Simulator
Shock Sync |
Energy output measurement |
|
Autoranged measurement
|
1.0 a 360.0 J
|
General |
|
Charging Time Measurement | 0.1s to 655s |
Voltage Range | 0 - 5000 V |
Current Range | 0 - 120 A |
Others |
ECG Simulator
Shock Sync |
Energy output measurement |
|
Autoranged measurement
|
1.0 a 360.0 J
|
Great stories are
for everyone even when only written for just one person. If you try to write with a wide, general audience in mind, your story will sound fake and lack emotion. No one will be interested. Write for one person. If it’s genuine for the one, it’s genuine for the rest.
General |
|
Operating Temperature |
10 °C a 40 °C (50 °F to 104 °F) |
Storage temperature |
-20 °C to +60 °C (-4 °F to +140 °F) |
Humidity |
10 % a 90 % non-condensing |
Dimesions |
(L)261mm x (H)212mm x (W)88mm |
Display |
7 Inches LCD Display |
Communications |
Wifi e Bluetooth |
Battery Charger |
100 - 240 V 50/60 Hz |
Battery |
12V e 6,6 Ah (on for 8 hours, according to usability) |
Weight
|
2 Kg |
ECG |
|
Amplitude |
0,5 a 2,5 mV |
Amplitude Variation |
± 2 % |
Pulse Rate |
Normal sinus - 30 - 300 bpm |
Ritmo Irregular - 30 - 300 bpm |
|
Atrial flutter- 30 - 300 bpm |
|
Asystole - 30 - 300 bpm |
|
Atrial fibrillation fine - 200 - 300 bpm |
|
Artrial fibrillation course - 200 - 300 bpm |
|
Triangular wave - 120 - 300 bpm |
|
Sine wave - 120 - 300 bpm |
|
Frequency Variation |
± 1 % |
Heart Rhythms |
Sinusal, Irregular, Atrial Fibrillation, Asystole, Fine and Gross Ventricular Fibrillation, Triangular and Sinusoidal Wave |
Energy |
|
Range (test) |
0.1 a 400J |
Energy Resolution |
0.1 J |
Reading variation |
± 2% |
Load Resistance |
50 Ohm ± 2% |
Voltage Range |
0 a 5000V |
Voltage Reading Variation |
± 3% |
Current Range |
0 a 100A |
Current Reading Variation |
± 3% |
Current Resolution |
0.1A |
Delay range
|
0 a 100ms |
Delay Reading Variation |
< 0.4ms |
Synchronization |
|
Measurement |
Peak of ECG R wave to peak of defibrillation pulse |
Range |
0 a 100ms |
Synchronization Accuracy |
< 0.4ms |
Timer |
|
Range |
0 a 59 min |
Pacer |
|
Default Resistance
|
25 Ω |
Range Resistance |
25 Ω / 50 Ω/ 75 Ω/ 100 Ω / 125 Ω/ 150 Ω / 175 Ω / 200 Ω / 500 Ω / 600 Ω / 1000 Ω/ 1500 Ω |
Voltage Range
|
0.1V a 33V |
Voltage Reading Variation |
± 0.5V |
Current Range |
0.1A a 1.3A |
Current Reading Variation |
± 0.5A |
Frequency |
5 a 200 BPM |
Frequency Reading Variation |
± 0.5 BPM |
Harrison - Electrosurgical Tester and Analyzer
Easily test all critical ESU functions using the Arkmeds Harrison Eletrosurgical Tester and Analyzer.
Harrison is capable of verifying and calibrating all major electrosurgical generators.
Key Features
Main frequency reading
Instantaneous and signal-averaging measurement mode
External resistors
Possibility of combination of resistors
Features
-
Multi-language;
-
LCD 7 inch Screen Touch Screen;
-
Robust, resistance, versatile on the field;
-
Bluetooth connection with app;
-
Test in accordance with IEC 60601 2-2;
-
CQM Test - Contact Quality Monitor;
-
Long lasting, rechargeable battery.
General |
|
Operating temperature |
10 °C a 40 °C (50 °F to 104 °F) |
Storage Temperature |
-20 °C to +60 °C (-4 °F to +140 °F) |
Humidity |
10 % a 90 % non-condensing |
Dimensions |
(L)261mm x (H)212mm x (W)88mm |
Display |
7 inches |
Communication |
Wifi e Bluetooth |
Battery Charger |
100 - 240 V 50/60 Hz |
Battery |
12V e 6,6 Ah (duração de 8 horas, de acordo com a modalidade de uso) |
Weight |
2,5 Kg |
Power |
|
Range |
1.0 - 400 Watts RMS |
Resolution |
0.1 Watts |
Variation |
± 5% reading |
Electric current |
|
Range |
0 a 20000 mA |
Resolution |
0.1 mA |
Variation |
± 5% reading |
Crest Factor |
|
Range |
1 a 999.9 |
Variation |
± 1% |
Frequency |
|
Range |
1kHz a 20Mhz |
Internal Resistance |
|
Value |
200Ω |
Variatio |
± 2.5% |
External Resistance |
|
Value
|
50Ω/ 100Ω/ 200Ω/ 300Ω/ 500Ω |
Variation |
± 1% |
Beginner
$ 35 .00
/ month- Basic sales & marketing for up to 2 users
- Account & Sales management
- No customization
- No support
Instant setup, satisfied or reimbursed.
Order nowProfessional
$ 65 .00
/ month- Complete CRM for any size team
- Get access to all modules
- Limited customization
- Email support
Instant setup, satisfied or reimbursed.
Start nowExpert
$ 125 .00
/ month- Unlimited CRM power and support
- Get access to all modules and features
- Unlimited customization
- 24x7 toll-free support
Instant setup, satisfied or reimbursed.
Contact us